Medium High Voltage Power Cable MV HV

Medium High voltage cables produced by ZMS can be used for more than 30 years. It is used for efficient transportation of medium-high voltage electricity.

ZMS Cable Manufacturer, as a professional supplier of medium and high voltage underground power cables, has more specialized cable sales representatives dedicated to serving the different needs of different customers.

Our standard medium voltage power cable underground transmission line composition includes single-core and three-core cables with copper or aluminum conductors.
It also includes sheath properties made of polyvinyl chloride (PVC), cross-linked polyethylene (XLPE), polyethylene (PE), ethylene propylene rubber (EPR), and low smoke zero halogens (LSZH).
As well as steel wire sheathing or aluminum wire sheathing for added mechanical strength and to provide mechanical protection.


ZMS power cable suppliers also highly recommend types of high voltage power cables, which are generally available in voltage levels from 35kv-220kv.

Such as high voltage overhead power lines and underground power cables.

The high power cable we offer includes British Standard, American Standard, European Standard, etc. Of course, we can also customize the type of high-voltage cables according to your needs.



Application

Medium and High voltage cables are used for overhead transportation of electricity, buried transportation of electricity, and submarine transportation of electricity.

medium voltage power cable

Standard

IEC 60228; IEC 60502; IEC 60840; IEC 62067

Construction

1. Conductor: Copper conductor, water blocked.

2. Conductor Screening: Extruded semi-conductive compound.

3. Insulation: XLPE.

4. Insulation Screening: extruded semi-conductive compound.

5. Separator: Swelling tape.

6. Core Sheath1: Lead Sheath.

7. Core Sheath2: Semi-conductive PE sheath.

8. Fillers: Polypropylene filler.

9. Fibre-optic Element: Fibre optic cable.

10. Separator: Binder tapes

11. Bedding: Bedding layer.

12. Armour: Galvanized steel wires filled with bitumen compound.

13. Serving: Polypropylene yarn.


Cable Selection

The main difference between medium and high voltage cables and general low voltage cables is their perfect shielding structure.

That is, it has two shielding structures conductor shielding and insulation shielding.

These two shielding layers are very closely related to the cable accessories.


LV MV HV Voltage Ranges


Low-voltage cables 0.6/1kV
Medium-voltage cables 3-35kV
High voltage cables 35-110kv
and ultra-high voltage cables 110-750kV

Low-voltage cables use ordinary PVC cables, polyethylene cables, and cross-linked polyethylene cables.
And the medium and high voltage cables are all cross-linked cables.
The 6kv-35kv ones are produced using three-layer co-extruded, high-density cross-linked polyethylene.
Common cable models are VV cable, YJV cable, VV22 cable, VV23 cable, YJV22 cable, and YJV23 cable.

The principles of selecting high, medium, and low-voltage cables.

The general principles for selecting cable cross-section, in order to achieve safety, reliability, economy, and technical reasonableness in power supply, the conductor cross-section should be determined according to the following principles.

(1) According to a long time allowable load a current selection of wire cross-section.
Make the wire work under the maximum load for a long time without overheating, that is, not to exceed its long-time allowable temperature.

(2) According to the allowable voltage loss select the cross-section of the wire.
So that the receiving end has sufficient voltage to ensure the quality of the power supply.

(3) Select the wire cross-section according to the economic current density.
So that the annual operating cost of the transmission line is the lowest, to achieve the purpose of economic power supply.

(4) Select the cross-section of the wire according to the mechanical strength.
Avoid breakage during operation or installation, or damage due to smashing pressure to ensure the safe operation of the power supply.

(5) Select the wire cross-section according to the thermal stability of the short-circuit conditions.
When the wire through the short-circuit current does not exceed its short-time allowable temperature.


Delivery And Shipping Services

While ZMS provides high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of ZMS

ZMS MV cable products and HV cable insulation wire packaging is provided in the form of wooden reels, corrugated boxes, and coils. 

The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.


Electrical Data

6/10(12)KV

Nominal Cross Section AreaCapacitanceInductanceCurrent Rating
mm2μF/mmmH/kmA
350.230.43167
500.260.41199
700.290.38241
950.320.37288
1200.350.35327
1500.380.34363
1850.420.33405
2400.470.32464


12/20(24)KV

Nominal Cross Section AreaCapacitanceInductanceCurrent Rating
mm2μF/mmmH/kmA
350.170.47171
500.180.44199
700.20.41243
950.220.4292
1200.240.38328
1500.260.37364
1850.280.35408
2400.310.34467


26/45(52)KV

Nominal Cross Section AreaCapacitanceInductanceCurrent Rating
mm2μF/mmmH/kmA
950.180.431.5
1200.190.421.6
1500.210.41.6
1850.220.391.8
2400.240.372
3000.260.362.2
4000.290.352.3
5000.320.332.6
6300.350.322.9
8000.380.313.1
10000.420.33.5

38/66(72.5)KV

Nominal Cross Section AreaCapacitanceInductanceCurrent Rating
mm2μF/mmmH/kmA
950.170.442
1200.180.432.1
1500.190.412.3
1850.20.42.4
2400.220.382.6
3000.240.372.8
4000.260.353.1
5000.290.343.5
6300.320.333.7
8000.350.324.1
10000.380.314.6

64/110(123)KV

Nominal Cross Section AreaCapacitanceInductanceCurrent Rating
mm2μF/mmmH/kmA
1850.140.462.8
2400.150.433
3000.170.413.5
4000.20.383.9
5000.220.374.3
6300.240.364.7
8000.260.345.2
10000.280.335.6

76/132(145)KV

Nominal Cross Section AreaCapacitanceInductanceCurrent Rating
mm2μF/mmmH/kmA
1850.130.473
2400.140.443.4
3000.160.423.8
4000.180.44.3
5000.20.384.6
6300.210.375.1
8000.230.365.6
10000.250.356.1

87/150(170)KV

Nominal Cross Section AreaCapacitanceInductanceCurrent Rating
mm2μF/mmmH/kmA
2400.130.473.4
3000.140.443.7
4000.150.424.1
5000.170.44.7
6300.190.385.3
8000.210.375.7
10000.230.366.3

127/220(245)KV

Nominal Cross Section AreaCapacitanceInductanceCurrent Rating
mm2μF/mmmH/kmA
5000.140.435.7
6300.160.416.4
8000.170.46.9
10000.190.387.4

160/275(300)KV

Nominal Cross Section AreaCapacitanceInductanceCurrent Rating
mm2μF/mmmH/kmA
5000.140.446.8
6300.160.427.7
8000.170.48.3
10000.180.399

Dimension and Weight

26/45(52)KV

Nominal Cross Section AreaNominal Conductor DiameterNominal Insulation ThicknessNominal Diameter Over InsulationNominal Lead Sheath ThicknessNominal Overall DiameterWeight
mm2mmmmmmmmmmkg/m
9511.2829.61.310920.8
12012.68311.311222.3
15014.2832.61.411624.4
18515.8834.21.411926.2
24018.1836.51.512429.5
30020.4838.81.613032.9
40023.2841.61.713637.9
50026.28451.814443.2
63029.8848.61.915249.7
80033.7852.52.116258.6
100037.9857.32.217368.1

38/66(72.5)KV

Nominal Cross Section AreaNominal Conductor DiameterNominal Insulation ThicknessNominal Diameter Over InsulationNominal Lead Sheath ThicknessNominal Overall DiameterWeight
mm2mmmmmmmmmmkg/m
9511.2931.61.311321.6
12012.69331.411623.8
15014.2934.61.412025.7
18515.8936.21.412428
24018.1938.51.612931.3
30020.4940.81.613434.3
40023.2943.61.714139.2
50026.29471.914945.4
63029.8950.6215752
80033.7954.52.116760.1
100037.9959.32.317870.7

64/110(123)KV

Nominal Cross Section AreaNominal Conductor DiameterNominal Insulation ThicknessNominal Diameter Over InsulationNominal Lead Sheath ThicknessNominal Overall DiameterWeight
mm2mmmmmmmmmmkg/m
18515.81650.2215640.9
24018.11550.5215742.5
30020.41450.8215744.1
40023.21351.6215947.2
50026.213552.116753
63029.81358.62.317660.7
80033.71362.52.418569.5
100037.91367.32.619780.5

76/132(145)KV

Nominal Cross Section AreaNominal Conductor DiameterNominal Insulation ThicknessNominal Diameter Over InsulationNominal Lead Sheath ThicknessNominal Overall DiameterWeight
mm2mmmmmmmmmmkg/m
18515.81854.22.116544.9
24018.11754.52.116646.3
30020.41654.82.116748
40023.21555.62.116851.1
50026.215592.317658
63029.81562.62.418565.2
80033.71566.52.519474
100037.91571.32.720685.4

87/150(170)KV

Nominal Cross Section AreaNominal Conductor DiameterNominal Insulation ThicknessNominal Diameter Over InsulationNominal Lead Sheath ThicknessNominal Overall DiameterWeight
mm2mmmmmmmmmmkg/m
24018.12162.52.418455.5
30020.42062.82.418557.3
40023.21963.62.418760.5
50026.218652.519065.1
63029.81766.62.519469.7
80033.71770.52.720479.8
100037.91775.32.821590.5

127/220(245)KV

Nominal Cross Section AreaNominal Conductor DiameterNominal Insulation ThicknessNominal Diameter Over InsulationNominal Lead Sheath ThicknessNominal Overall DiameterWeight
mm2mmmmmmmmmmkg/m
50026.22477.62.921981.3
63029.82379.2322486.7
80033.72383.13.123495.3
100037.92387.33.1241104

160/275(300)KV

Nominal Cross Section AreaNominal Conductor DiameterNominal Insulation ThicknessNominal Diameter Over InsulationNominal Lead Sheath ThicknessNominal Overall DiameterWeight
mm2mmmmmmmmmmkg/m
50026.22681.62.922984.7
63029.82481.2322888.9
80033.72485.13.123797.6
100037.92489.33.1247106.3


Power Cable

Power cables are used to transmit and distribute electrical energy. Power cables are commonly used in urban underground power grids, power station lead-out lines, power supply within industrial and mining enterprises, and over-the-river transmission lines.

There is no news related to this product.

CORPORATE SOCIAL RESPONSIBILITY

ZMS Cable have a wide product scope, includes: Power cables up to 500kV, AAC, AAAC, ACSR conductors, ABC Cable,electric wires, instrument cable, telecommunications cable, Stay wires. With advanced manufacture technology, rich human resource and effective management system, we guarantee all products are manufactured strictly in accordance with GB, IEC, BS, NFC, ASTM, DIN standards,etc. Beyond quality control, ZMS have been trying its best to offer much higher standard of services rather than expected.

The Adjuster
All customised cables designed by our cable engineer will be subject to testing to relevant standards and appropriate performance criteria. Bespoke cable testing will be conducted under our CNAS accreditation where appropriate. Where required by industry or application, we can submit for relevant cable certification and cable approval processes. For more information or to discuss possible custom designed cable solutions, please complete an enquiry form, contact our technical experts on the Technical Hotline +86 (0)371 6782 9333, or email:sales@zmscable.com

The Zms Cable Advantage

You can contact us in the following ways:

email to sales@zmscable.com OR click Inquiry

INQUIRY
主站蜘蛛池模板: 国产人无码a在线西瓜影音 A级毛片高清免费视频在线播放 | 91视频影院 | 可以在线观看的av网站 | 夜鲁夜鲁很鲁在线视频视频 | 俺去啦最新网址 | 高清国产精品人妻一区二区 | 男人a天堂2814| 久久成人高清视频 | 国产99久久久国产 | 亚洲AV无码一区二区三区18 | 免费超碰在线 | 亚洲一本之道高清乱码 | 亚洲欧美另类成人综合图片 | 天天操天天插天天干 | 亚洲国产精品久久久久婷婷图片 | 国产精品久久免费视频 | 蜜桃国精产品二三三区视频 | 久久久久夜色精品国产老牛91 | 91亚洲成a人片在线观看www | 久久不见久久见www日本 | 中文字幕11 | 7777888色淫网站免费视频 | 91精品久久久久久久久不卡 | 国产精品国产三级国产aⅴ中文 | 日韩一二三区在线观看 | 欧美午夜无码大片免费看 | 人妻18毛片A级毛片免费看 | a人成日韩视频在线观看 | 男女午夜猛烈啪啦啦视频 | 亚洲AV综合色区手机无码一区 | 被黑人各种姿势猛烈进出视频 | 老师好湿好紧我要进去了在线观看 | 成人午夜视频在线观看免费 | 欧美精品久久久久久久久久丰满 | 久久精品国产av一区二区蜜臀 | 欧美最猛黑人xxxx黑人猛叫黄 | 91青青在线视频 | 成年人一级黄色片 | 99久久国产这里只有精品 | 国产在线午夜 | 99在线亚洲|