What are the main methods of power cable withstand voltage test?

2 years ago 2082 0 News


The main methods of power cable withstand voltage test


A cable withstand voltage test is a way to find faults in the presence of cables. It is easily affected by various factors during the test, resulting in problems such as failure and short circuits. 

The main methods of several cables to withstand voltage tests are described below.

First, ultra-low frequency withstand voltage test

1562638173494213.png

The ultra-low frequency (0.1Hz) withstand voltage test method first appeared in 1980, and it is mainly a non-destructive test method for observing whether there is an insulation defect in cable operation, and the method has been verified by a large number of laboratory tests and field tests. 

The low-frequency withstand voltage test has a good application effect in the low-voltage power cable withstand voltage test. 

The method utilizes the principle of converting 50 Hz alternating current into direct current voltage through rectification and filtering, and then converting the direct current voltage into an alternating current voltage of 1 kHz through an inverter circuit, and then performing amplitude modulation processing by a 0.1 Hz sinusoidal oscillator, and after amplitude modulation, 1 kHz. 

The amplitude wave such as the AC voltage is converted into a 0.1 Hz varying beam wave. 

It is mainly based on the high voltage formed between the high voltage transformer and the voltage multiplying circuit, which is mainly characterized by a sine wave and is mediated by a varistor so that the high AC voltage load output is a 0.1 Hz high voltage sinusoidal waveform. 

The advantages of the ultra-low frequency withstand voltage test are mainly: 1 no damage; 2 high accuracies; 3 small sizes, easy to carry. However, the output voltage level of this method is low, and it is mainly used in the medium and low voltage cable withstand voltage test.

Second, the modulated power frequency series resonance test

The method mainly utilizes the inductive reactance of the reactor and the capacitive reactance of the measured cable capacitance to generate a resonance in a 50 Hz power frequency environment, and a high voltage is generated in the process. The advantages of the modulated power frequency series resonance test are: 

1 The output current waveform is basically a sine wave.

2 Is high in specificity, and only after the series resonant circuit satisfies the condition for generating resonance, a high voltage is formed, and the cable to be tested is once tested. 

If there is a problem, it will cause a loop abnormality, which is equivalent to a short circuit of the cable. 

The high voltage will also appear to be uniformly dropped. 

Moreover, since the reactor can limit the short-circuit current, the protection device is not affected, and thus it is not necessary to install a resistor protection device. 

The disadvantage of this test method is that the operation is complicated, the system quality factor is not high, the automation level is low, and the noise is large, which limits its application in practice.

1562638215827306.png

Third, the frequency conversion series resonance test

The principle of frequency conversion series resonance test is similar to the above-mentioned principle of modulated power frequency series resonance test. 

The difference is that the frequency conversion series resonance test realizes the resonance of the test circuit by adjusting the output voltage frequency in the variable frequency power supply.

In the frequency series resonance test, the resonance of the test circuit is realized by the inductance generated by the regulating reactor at the 50 Hz power frequency. 

The advantage of the variable frequency series resonance test is that when the required power supply capacity of the test is lower than the power supply capacity of the cable under test, the test can be performed at much lower power than the required power supply, which can effectively improve the efficiency of the field test and can overcome.

The shortcomings of the modulated power frequency withstand voltage test device make it more widely used in real life. 

In addition, the operating frequency of the variable frequency series resonance test is only 30 to 300 Hz, which can improve the problem that the frequency of the ultra-low frequency withstands voltage test is too low and the loss is small, which is inconsistent with the actual loss. 

Therefore, the results obtained by the variable frequency series resonance withstand voltage test are precise, comprehensive, and reliable.


@ZMSCABLE MANUFACTURER


Tags:
Power Cable
INQUIRY
主站蜘蛛池模板: 久久夜精品va视频免费观看 | 边摸边吃奶边做爽gif动态视频 | 99久在线观看 | 欧州精品 | 韩国美女一级毛片 | 日本在线不卡视频一二三区 | JK小仙女自慰流白浆呻吟 | 精品国产乱码久久久久久影片 | 又黄又爽又猛的视频免费 | 亚洲天堂福利视频 | 麻豆免费观看网站 | 久久久亚洲男人的天堂一区二区三区 | www.久久综合 | 性色av一区二区三区 | 成人亚洲一区无码久久 | 亚洲日韩精品射精日 | 亚洲日韩中文第一精品 | 亚洲精品一线二线在线播放 | 草久在线观看 | 99久久国产精品一区二区三区 | 男子操女子视频 | 国内少妇BBWBBw黑森林 | 久久国内 | 久热中文字幕 | 成人三级黄色片 | 国产特色特黄的视频免费观看 | 欧美高潮在线 | 野花高清在线观看免费8 | 操操操爱爱爱 | 欧美日韩在线一区二区三区 | 欧美1区2区在线观看 | 亚洲精品国产精品国产 | a级免费毛片 | 亚洲综合免费视频 | 久碰香蕉线视频在线观看视频 | 欧美日在线观看 | 欧美城天堂网地址 | 91大神一区二区三区在线观看 | 国产一区精品在线 | 日韩成人国产 | 视频二区精品中文字幕 |