sales@zmscable.com

What are Overhead Cables?

3 years ago 1835 0 News

overhead cable 0519.jpg

Overhead harness cables are overhead power lines that use multiple insulated phase conductors tightly bundled together, usually with an exposed neutral conductor. This contrasts with the traditional practice of using uninsulated conductors separated by air gaps. This variant of overhead power lines utilizes the same principles as bundled conductors, except they are closer to the point of contact, but each conductor is surrounded by insulation.

 

The use of overhead cables can greatly reduce various short-circuit faults. Compared with overhead bare conductors, the failure rate is 4-6 times lower.

 

Advantages of Overhead Cables

Aerial-Bundle-Cable-LV286-.jpg

ABC can omit one of these connectors. Reduces the risk of only the neutral wire breaking due to tree or vehicle damage. Higher reliability compared to bare conductor overhead and underground systems.

 

Power supply security is good. The use of overhead cables can greatly reduce personal electric shock casualties. When the overhead cable is energized, when the human body or other animals accidentally touch the insulating surface of the cable, as long as the cable is not broken down, it will not cause harm to people and animals.

 

Erection and maintenance are convenient. Aerial cables can be run on any type of poles and towers or along walls. In special cases, it can also be directly fixed to the tree pole with hardware through the tree.

 

Economically reasonable. Although using overhead cables is more expensive than using overhead bare conductors, it is cheaper than ordinary underground installation cables. Therefore, its comprehensive cost is significantly lower, more economical and more reasonable.

 

Relatively immune to short circuits caused by external forces (wind, fallen branches) unless they wear down the insulation. Can stand near trees/buildings and wont spark if touched. Almost no tree trimming is required, and installation is simpler as no crossbars and insulators are required.

 

Failure of Overhead Cables

The main objection to traditional designs is that multiple conductors are considered unattractive and external forces can cause them to touch and short out. The resulting sparks are what cause bushfires in dry climates.

 

In humid climates, tree growth is a significant problem for overhead power lines. Overhead bundled cables will not arc if they hit a branch. While constant friction is still a problem, the cost of pruning trees can be reduced. Areas where large trees and branches fall off the line are a problem for overhead bundled cables as the line degrades over time. Insulation cracks and breaks due to very large strains can lead to short circuit failures and then ground fires due to dripping of molten insulation.

 

Low voltage ABC has been developed in several countries around the world and promises to be cheaper, safer, more reliable, require less tree clearing and pruning, be more aesthetically pleasing, require less effort, require less maintenance and eliminate the risk of conductor collisions bushfires.


Here at ZMS, you can get more information about cable products.

 

INQUIRY
主站蜘蛛池模板: 国产一区三区在线 | 黄色片国产片 | 2019国产精品 | 中文高清无码人妻 | 在线这里只有精品 | 国产在线欧美 | 51久久久| 亚洲成人精品久久 | 一级片久久免费 | 免费费很色视频大片 | 国产日产欧洲无码视频无遮挡 | 性按摩aaaaaa视频 | 偷玩朋友的醉酒人妻中文字幕 | 特级做a爰片毛片免费看1o8 | 国产精品一区二区在线播放 | AAA级大胆免费人体毛片 | 超碰在线色 | 亚洲国产欧美一区二区三区久久 | 日本特黄视频 | 少妇被黑人4P到惨叫 | 国产v欧美Ⅴ日韩v在线观看 | 蝌蚪久久| 亚洲乱码日产精品bd | 91精品一区二区三区蜜臀 | 色悠久久久久综合网伊 | 国产成本人片无码免费 | 国产人成无码视频在线1000 | 99这里有精品热视频 | 成人免费无码成人影院日韩 | 久久棈精品久久久久久噜噜 | 亚洲最大日韩中文字幕另类 | 国产亚洲日韩在线三区 | 老司机免费视频一区二区三区 | 综合激情久久综合激情 | 日本一级特黄录像视频播放 | 精品视频手机在线观看 | 91黄在线观看 | 香蕉久久国产AV一区二区 | 九九九热精品 | 亚洲欧美日韩在线一区二区三区 | 日韩天码|