Main factors that heat the wires and cables during operation

2 years ago 3556 0 News

The main factors that make the wire and cable hot during operation


With the development of electricity, there are more and more aspects of relying on electricity in life, and the importance of wire and cable is also highlighted. We know that wire and cable are used for power transmission. 

If the wire and cable continue to heat up during operation, the temperature of the wire and cable will be too high. 

If short, it will cause a short circuit trip, and heavy will cause fire, so use wire and cable. Special care must be taken when the heat is generated during operation. 

The following are the six major factors that lead to power cable heating during operation.

1567646263980282.png 

1. The cable conductor resistance does not meet the requirements, forming a hot scene of the cable during operation.

2. The cable selection type is improper. The conductor cross-section of the formed cable is too small, and the overload phenomenon occurs during operation. After long-term use, the cable's heat and dissipation are unbalanced to form a fever scene.

3. When the cable device is placed too densely, the ventilation and heat dissipation effect is not good, or the cable is too close to other heat sources, which affects the normal heat dissipation of the cable, and may also form a hot phenomenon in the operation of the cable.

4. The joint manufacturing skills are not good, the crimping is not tight, and the contact resistance at the joint is too large, it will also form a cable episode fever.

5. The cable phase insulation function is not good, the formation of insulation resistance is small, and the operation will also have a fever scene.

6. The partial sheath of the armored cable is damaged. After the water enters, the insulation function is slowly destructive, and the insulation resistance is gradually reduced, forming a fever phenomenon during the cable operation.

After the power cable has a fever scene, if the fault is not found, the cable will continue to be connected to the power supply and the insulation heat breakdown will occur. The formation of a cable attack phase-to-phase short-circuit trip scene, severe may lead to a fire.

In order to ensure the safe operation of the cable, the following factors should be considered when selecting power cables for cable design:
1. The cable's rated voltage should be greater than or equal to the rated voltage of the power supply system at the installation point.
2. The cable continuous allowable current should be equal to or greater than the maximum continuous current of the supply load.
3. The core cross-section to meet the requirements of the stability of the power supply system in the event of a short circuit.
4. According to the cable length verify whether the voltage drop meets the requirements.
5. The minimum short-circuit current at the end of the line should enable the reliable operation of the protection device.
6. High breakdown strength, and low dielectric loss.
7. A relatively high insulation resistance, and excellent discharge resistance.
8. With a certain degree of flexibility and mechanical strength, insulation performance has long-term stability.

Tags:
Power Cable
INQUIRY
主站蜘蛛池模板: 久久靠逼 | 日本播放一区二区 | 国产主播av在线 | 久久99精品国产99久久6男男 | 久久精品国产网站高清综合 | 久久久www| 国产亚洲精品久久久久久无挡照片 | 亚洲码国产精品高潮在线 | 国产一卡三卡四卡无卡精品 | 满天神佛国语免费观看 | 国产在线高清视频无码不卡互動交流 | 国产成a人片在线观看视频99 | 国产精品一品二区三区的使用体验 | 色欲AV午夜一区二区三区 | 在线观看a级 | 超级碰碰青草免费视频 | 免费中午字幕无吗 | 国产人无码a在线西瓜影音 A级毛片高清免费视频在线播放 | chinese性内射高清5 | 日本淫片 | 9区中文字幕在线 | 亚洲国产精品免费在线观看 | 伊人色综合视频一区二区三区 | 黄色wwwwwww| 女人与zzzooooxxxx| 色欲aⅴ亚洲情无码AV | 91不卡| 色一情一乱一伦 | 中文字幕熟女人妻av一区二区三区 | 亚洲欧美成人在线 | 色综合一 | 亚洲国产精品一区二区三区四区 | chinese中国人妻4p对白视频 | 国产高清一区二区三区四区 | 国产精品久久久久久影视不卡 | 人妻偷人VA精品国产旡码 | 亚洲国产精品成人 | 不卡一二三 | 中文字幕国产亚洲 | 亚洲日韩制服丝袜中文字幕 | 国产精品久久久久久久久侵犯 |