Identification of Poor Quality Wire and Cable


There are several tips for identifying inferior insulated wires:


1 Ordinary Wire


1.1 Look at the printed words on the label and the insulation skin. 

If there are typos or prints of different shades and ambiguous words, attention should be paid.


1.2 Using the fingers to insulate the outer skin, some inferior insulated wire sheaths are easy to fade, especially the red line will have this problem. 

After the smashing, the color of the line on the finger or the word on the printed line is erased. 

Generally speaking, it is inferior quality.


1.3 Using the nails to cut and smash the outer skin, it is generally inferior to the line that can be drawn down and smashed down.


1.4 Repeatedly bending the insulated wire, the inferior wire insulation layer is generally poor in material, and the insulation layer will break after bending for 3 to 4 times.


1.5 Ignite the insulation layer, which is inferior to the spontaneous combustion after leaving the open flame.


1.6 Look at the core color, the inferior line color is gray and has no metallic luster.


1.7 In the package length, generally 100 meters per tie or circle, the national allowable error is ±0.5%, the inferior wire length is only 95 meters, or even less.

Some are misleading in the package on the basis of "code".


1.8 If it is still undetermined by the above 7 methods, it is also possible to measure the outer diameter of the insulated wire and the core diameter. 

The measured values differ greatly, basically the inferior insulated wires.

(Note: there are many bad manufacturers at present, the conductors are not enough cross-section. Increase the thickness of the insulation or sheath to reach the entire outer diameter of the wire to deceive the user).


2 Halogen-Free Low-Smoke Environmental Protection Wire


At present, domestic technology or raw material problems can only ensure that the insulation capacity of halogen-free low-smoke flame-retardant wires is not damaged by high temperature and humid environment, instead of radiation-crosslinked halogen-free low-smoke flame-retardant wires

Even after the warm water test, problems have arisen in design engineering applications. 

In 2005, after the non-irradiation cross-linked halogen-free low-smoke flame-retardant wires used in a civil engineering project in Nanjing were laid in a humid environment, the faults of insufficient insulation strength of multiple lines could only be replaced. 

There are many design institutes in China. 

For example, the Beijing Architectural Research Institute's Olympic project, Beijing West Railway Station underground shopping mall, Guangdong Science Center main building, etc.

Shall stipulate that non-irradiated and cross-linked halogen-free low-smoke flame-retardant cables shall not be used in the project. 


Because non-irradiated cross-linked halogen-free low-smoke flame-retardant wires are particularly easy to absorb water (thermoplastic halogen-free low-smoke materials use a large amount of AL(OH)3 or Mg(OH)2), according to the National Wire and Cable Testing Center experiment: Non-irradiated cross-linked halogen-free low-smoke flame-retardant wires have a 100-1000 times lower insulation resistance after warm water experiments.


Therefore, it is very simple to identify such wires. Is it necessary to see if the production company has an irradiation cross-linked cable production line?


3 Refractory Wire


Identifying such inferior wires, the mica tape should be identified on the basis of ordinary wires.


3.1 Generally, a 2-layer mica tape is used for wrapping, and the overlap ratio is about 50%.


3.2 The quality of the mica tape is also critical. It is gently rubbed by hand. If there is powder, it is inferior.


3.3 Burning mica with flame, if the flame passes through the mica tape, it is a poor quality fire-resistant wire.


Electrician Knowledge


Power P=I2×R where: I——current R——conductor resistance


R is inversely proportional to the cross section S of the conductor.

That is to say: the inferior wire cuts the material on the conductor section, which not only causes the wire conductor to overheat and the insulation aging. Thereby causing the danger of electrical fire and loss of electric energy. 

For example, if the cross section is only 90%, then 10% more power is consumed than the conductor of the standard cross section.


In short, if the use of inferior wires, it will produce: 

1 Insulation is easy to breakdown or premature aging, resulting in leakage.

2 Wire heating is very powerful.

3 Electrical energy consumption.

4 Easily lead to fire, causing human and animal casualties.


As the saying goes, "a penny, a share of goods", I hope that consumers must be cautious when choosing to purchase wires! 

In fact, you are not only purchasing products, but you are also purchasing a type of safety and insurance.


INQUIRY
主站蜘蛛池模板: 四虎永久在线精品免费A | 小12萝裸体视频国产 | 在线观看热码亚洲av每日更新 | 在线aⅴ亚洲中文字幕 | 国产三区在线观看视频 | 久久久亚洲欧洲日产AV | 大地资源网中文第五页 | 久久精品国产68国产精品亚洲 | 91精品国产一区二区三区在线 | 97人人添人人爽一区二区三区 | 精品综合久久久久久99粉芽 | 久久久久久久尹人综合网亚洲 | 精精国产视频 | 日本天天躁狠狠躁噜噜噜 | 2020日日夜夜噜噜噜com | 边摸边吃奶边做爽gif动态视频 | 港台一级毛片 | 人妻系列无码中文字幕专区 | 美女不带套日出白浆免费视频 | 国产精品入口福利 | 老熟妇性老熟妇性色变态 | www久久国产 | SM调教室论坛首页入口 | 国产精品无码免费热播 | 国产一区二区网 | 日本老妇人乱xxy | 日韩午夜精品免费理论片 | 免费无码一区二区三区蜜桃大 | 日本人在线看片免费观看 | 欧美日韩一区二区在线视频播放 | 蜜桃在线一区 | gav成人免费播放器 真实国产精品视频400部 | 国产午夜成人久久无码一区二区 | 大肉大捧一进一出好爽视色大师 | 亚洲AV无码AV在线播放 | 久久99精品国产自在现线小黄鸭 | 狠狠躁天天躁中文字幕 | 成人在线免费观看视频网站 | 亂倫近親相姦中文字幕视频 | 国产免费AV片在线观看播放器 | 久久成人高清视频 |