Common fault types and characteristics of overhead cables

2 years ago 2186 0 News

Common fault types and characteristics of overhead cables


Overhead transmission lines are the main components of the power system and transmission network. 

They undertake most of the industrial and domestic transmission tasks and are also the most vulnerable parts of the power system. 

The common faults are classified according to their nature. They are mainly divided into transient faults and permanent faults. 

The transient faults mainly include flashovers caused by lightning overvoltage and short circuits caused by birds. 

The permanent faults are primarily due to the climate or the equipment itself. 

Caused by other reasons, such as ice and snow weather or line aging, etc., transient overvoltage breakdown of the transmission line insulation, equipment installation, storms, earthquakes, etc.

1564630261775704.png

Caused by permanent short circuits of transmission lines. 

According to the specific classification, it can be divided into horizontal and vertical faults. 

The horizontal faults are mainly single-phase two-phase, and three-phase short circuits. 

The vertical fault mainly has one-phase and two-phase disconnection problems. These faults can easily cause the transmission line to trip. 

Accidents, so you need to find out the cause of the fault the first time of the fault, solve the problem in a targeted manner, or take precautions against a fault in advance.

Lightning weather hitting overhead transmission lines is very easy to form an overvoltage inside the line. This overvoltage is also called external overvoltage because it originates outside the power system. 

It is usually divided into induction and direct lightning overvoltage, and the overvoltage is the most. 

It is easy to cause flashovers and tripping inside the line. Lightning flashover discharge is mainly caused by tripping, which will form obvious discharge marks on the surface of the transmission line insulator

A lightning strike may cause the permanent failure of the transmission line. 

Usually due to the complete failure of the porcelain insulator of the transmission line, the break of the lightning rod, or the disconnection of the grounding line, etc. during the lightning strike.

The insulation of the transmission line needs to be safely transmitted even under internal and external voltages and long-time voltage operation. 

However, the long-term operation will cause pollution on the surface. 

These pollutions are easy to reduce the insulator itself in weather such as fog, rain, and melting snow. 

The stain resistance strength causes the transmission line to form a dirty flashover fault during the delivery voltage. 

Contamination flashover accidents are generally prone to occur in humid weather, such as light rain, sleet, etc. In the rain or heavy rain, the rain will wash away the dirt on the surface of the line, and the phenomenon of flashover will be less due to autumn. With less rain in winter and easy-to-form wet weather such as fog.


INQUIRY
主站蜘蛛池模板: 国产高潮流白浆啊免费A片动态 | 狠狠躁天天躁夜夜添人人 | 人妻无码AV中文系列久久兔费 | 国产一区二区三区四区三区四 | 国产精品麻豆传媒 | 国产一级义婬片AAA毛片久久 | 羞羞答答xxdd在线网站 | 97国产在线 | 国产日产精品一区 | 邻居少妇张开腿让我爽了一夜 | 国产精品视频合集 | 精品1区2区 | 国产精品国产三级国产AV中文 | 国产亚洲精品中文字幕 | 春色校园亚洲愉拍自拍 | 久久99日韩 | 九九久久久久 | 99精品久久久国产一区二区三 | 国产卡一卡二卡乱码 | 亚洲国产精品免费在线观看 | 日本日本乱码伦视频在线观看 | 一级国产片 | 91大片在线观看 | avtom影院永久地址 | 日韩码有限公司在线观看 | 99er在线观看视频 | 久久不见久久见免费影院视频观看 | 亚洲一区二区二区久久成人婷婷 | 日本系列1页亚洲系列 | 曰韩内射六十七十老熟女影视 | 筋肉雄汁gay雄汁外送网站 | 国产91精品欧美 | 欧美3p两根一起进高清免费视频 | 亚色网址| 5566日本婷婷色中文字幕 | 欧美在线爱 | 久久午夜无码免费 | 亚洲AV无码专区在线亚 | 久久久久久色 | 国产va亚洲va在线va | 国产精品18久久久不卡最新章节 |