Causes and hazards of moisture in XLPE insulated overhead lines

2 years ago 1879 0 News

1559703141584554.png


The causes and hazards of moisture in XLPE-insulated overhead lines


In urban power grid reconstruction projects, cables, especially XLPE-insulated overhead lines(including aluminum ABC cable, ABC cable 35mm, PE insulated ABC cable), have been widely used. 

However, due to the particularity of the cable, there are special requirements for the installation, operation, and maintenance of the cable. 

Cable dampness or water ingress reduces the insulation resistance of the cable, which is an important aspect of the cable line running accident.


Causes and hazards of cable flooding:


(1) When the new whole cable is shipped from the factory, both ends are sealed with plastic sealing sleeves. 

However, after the construction site is used according to the actual situation, the remaining part is simply wrapped with plastic cloth to break the gap. It is placed in the open air and the seal is not good. 

For a long time, it will inevitably have water vapor infiltrated into the cable.


(2) When the cable is laid, it needs to be transported for a long time. 

Due to weather or other reasons, a lot of water is often accumulated in the cable trench. 

During the laying process, the cable head is inevitably immersed in the water due to plastic. 

If the cloth is not tightly wrapped or damaged, the water will enter the cable. 

In addition, when the traction and the pipe are worn, the insulation is sometimes scratched. This phenomenon is particularly prominent when using mechanical traction.


(3) After the cable laying is completed, the cable head is not produced in time due to the limitation of on-site construction conditions, so the unsealed cable breakage is exposed to the air for a long time, even immersed in water, so that the water vapor enters the cable in large quantities.


(4) During the cable head-making process (including the terminal head and the intermediate joint), the newly handled cable ends may accidentally fall into the accumulated water on the site due to the negligence of the construction personnel.


(5) In the normal operation of the cable, if a breakdown such a breakdown occurs for some reason, the water in the cable trench will enter the cable inside the fault point.

In civil construction, especially when using large construction machinery.

It is not uncommon for a construction site to have cable breakage or breakdown due to various human factors. In the event of such an accident, cable insulation is severely damaged and the cable is also flooded.


After the cable enters the water, under the action of the electric field, aging will occur, and finally, the cable will break down.


INQUIRY
主站蜘蛛池模板: 高潮流白浆潮喷在线播放视频 | 99久久久久久中文字幕一区 | 免费又黄又硬又爽大片 | 免费中文字幕日产乱码 | 日韩美女在线 | 亚洲av片毛片成人观看兔费 | 欧美精品久久久久久久监狱 | 欧美乱大交xxxxx春色视频 | 亚洲第一av片精品堂在线观看 | 亚洲国产天堂久久国产91 | 翁公粗大挺进王丽霞高潮嗨文 | 爱爱视频免费看 | 成人午夜性a一级毛片免费看 | 性无码专区无码片 | 久久夜色精品国产噜噜亚洲SV | 亚洲AV无码乱码在线观看裸奔 | 91麻豆精品国产91久久久更新资源速度超快 | 在线免费观看福利 | 91精品婷婷色在线观看 | 中文字幕亚洲欧美另类 | 一本色道久久综合精品竹菊 | 日韩高清免费在线 | 亚洲精品在线免费看 | 一区二区成人精品 | 日韩中文字幕在线视频观看 | 延禧攻略免费在线观看 | 国产高潮好爽受不了了夜夜做 | 越做高潮越喷奶水视频 | 成人国产精品免费网站 | 男吃奶玩乳尖高潮视频 | 丰满少妇高潮叫久久国产 | 91高跟黑色丝袜呻吟在线观看 | a亚洲视频 | 四虎影院wwww| 久久在线免费观看视频 | 深夜放纵内射少妇 | 成人高清videosex高潮 | 国产高清视频一区二区在线观看 | 黄色一视频 | 国产美女在线精品 | 99热国品|